Laboro

NYC special and progress inspections: the TR1 list, in full

The 20 special inspections under BC 1704/1705 and the 5 progress inspections under 1 RCNY 101-06, with their code references and the phase each one lands in.

What is a TR1 in NYC construction?

TR1 is the DOB Technical Report — Statement of Responsibility. It lists the special and progress inspections that apply to the job and names the agency or agent responsible for each one. It is sealed by the Registered Design Professional, not by the project manager. TR8 is the separate energy-code report.

The DOB technical reports

TR1

Technical Report — Statement of Responsibility. Lists the applicable special inspections and progress inspections and the agency/agent responsible for each one.

TR8

Technical Report — Energy Code Progress Inspections.

TR3

Technical Report — used for crane/derrick and certain equipment.

Special inspections — BC 1704 / 1705

InspectionCodePhase
Structural Steel — WeldingBC 1705.2 / AWS D1.1Structural steel erection
Structural Steel — High-Strength BoltingBC 1705.2 / RCSCStructural steel erection
Structural Steel — DetailsBC 1705.2.2Structural steel erection
Concrete — Cast-in-PlaceBC 1705.3 / ACI 318Concrete structure (foundation, slabs, columns, walls)
Post-Installed AnchorsBC 1705.37 / ACI 318 Ch.17Any phase with anchors in hardened concrete
MasonryBC 1705.4 / TMS 402/602Erection of structural masonry walls
Soils / SubgradeBC 1705.6Excavation and foundation preparation
Deep Foundations (Piles / Drilled Piers)BC 1705.7 / 1705.8 / 1705.9Pile driving/drilling
Sprayed Fire-Resistant Material (SFRM)BC 1705.14Fire protection of the structure
Penetration & Joint FirestoppingBC 1705.17 / 110.3.5Closing of fire-rated walls/slabs (MEP rough-in and after)
Mechanical SystemsBC 1705.21 / 28-116.4HVAC installation
Fuel-Gas / Fuel-Oil PipingBC 1705.22 / 1705.23Installation of gas or fuel piping
Sprinkler SystemsBC 1705.30 / NFPA 13Fire suppression (sprinkler) installation
Standpipe SystemsBC 1705.31 / NFPA 14Standpipe installation
Smoke Control SystemsBC 1705.18Smoke control commissioning
Combustible Exterior Wall Coverings (EIFS / MCM)BC 1705.16Facade / building envelope
Wind / Seismic ResistanceBC 1705.11 / 1705.12 / 1705.13Lateral-force-resisting system (throughout the structure)
Wall Panels, Curtain Walls and VeneerBC 1705.20Facade / cladding attachment (above 40 ft)
Tenant Protection Plan ComplianceBC 1705.26Throughout the work while dwelling units are occupied
Mastic and Intumescent Fire-Resistant CoatingsBC 1705.15Fire protection of exposed steel

Progress inspections — 1 RCNY 101-06

InspectionCodePhase
Structural Stability — Existing BuildingsBC 1705.25When there is demolition/alteration adjacent to or over an existing structure
Energy Code Progress Inspections (TR8)1 RCNY 5000-01 / NYCECCThroughout the whole job (envelope, MEP, lighting)
Fire-Resistance Rated Construction1 RCNY 101-06 / 110.3.xClosing of fire-rated assemblies
Final InspectionAC 28-116.2.4.2 / 1 RCNY 101-10Project closeout (prior to CO/sign-off)
Elevator / Conveying Systems1 RCNY 101-06 / ASME A17.1Elevator installation and testing