Construction hoist power: the electrical permit behind the hoist
A material or personnel hoist requires its own electrical permit for power, separate from the hoist equipment filing — a small line item that is routinely missed at bid.
Last checked: Oct 23, 2026
Key facts
- Two permits the hoist itself (BC 3316.4) and its power (an electrical permit)
- Power installed under a licensed electrician’s permit, filed in DOB NOW
- Electrical code 2025 NYC Electrical Code, in full effect since December 21, 2025; Article 590 for temporary installations
- Scaffold hoisting equipment over 2,000 lb on a supported scaffold needs the scaffold permit at any height
Does a construction hoist need an electrical permit?
Yes. When a project uses a hoist, powering it requires an electrical permit of its own, filed under a licensed electrician and separate from the equipment filing for the hoist itself.
Key considerations
Separate from the hoist filing
The hoist itself needs a DOB permit before it is installed (BC 3316.4; material and bucket hoists BC 3317, personnel hoists BC 3318). DOB treats a temporary hoist as construction equipment, not an elevator. Its power supply is a second permit and a second trade.
A licensed electrician
Temporary power for the hoist is installed under a licensed electrician’s permit, following the 2025 NYC Electrical Code (in full effect since December 21, 2025; Article 590 covers temporary installations).
Only when a hoist is specified
Most facade repair projects rely on suspended or supported scaffolds rather than a hoist; the permit applies only when a hoist is part of the access plan.
It also affects the scaffold permit
A supported scaffold with hoisting equipment rated over 2,000 lb loses the BC 3314.2 permit exemption, regardless of its height.
Price it with the hoist
Whenever a hoist appears in the access plan, include the electrical permit, the temporary power connection and the electrician’s time in the bid.
Checklist: a hoist on the job
- Check the access plan for a hoist: material, bucket or personnel.
- Price the hoist permit, the electrical permit, the temporary power connection and the electrician’s time.
- File the electrical permit for the hoist power under a licensed electrician.
- If the hoist sits on a supported scaffold and is rated over 2,000 lb, file the scaffold permit too.
Sources
- 2022 NYC Building Code, Chapter 33: Safeguards during construction or demolition
- NYC DOB, 2025 NYC Electrical Code (in full effect December 21, 2025)
- NYC DOB, Electrical permit
- NYC DOB, Temporary hoists
- NYC DOB, Project requirements for design professionals: temporary hoists
Checked against the official text on October 23, 2026.